{"product_id":"hgl-3-pole-load-break-switch-100a-to-1600a-industrial-isolation-power-switching-solution","title":"HGL 3 Pole Load Break Switch – 100A to 1600A Industrial Isolation \u0026 Power Switching Solution","description":"\u003cp\u003eThe \u003cstrong\u003eDelixi HGL Series Load Break Switch (LBS)\u003c\/strong\u003e is engineered for safe power isolation, circuit disconnection, and industrial electrical switching applications. Designed for demanding commercial and industrial environments, the HGL series provides dependable load switching performance with high operational reliability.\u003c\/p\u003e\n\u003cp\u003eBuilt according to \u003cstrong\u003eIEC 60947-2 international standards\u003c\/strong\u003e, the HGL Load Break Switch delivers secure electrical isolation and controlled switching for low-voltage distribution systems, industrial machinery, power panels, and energy infrastructure.\u003c\/p\u003e\n\u003cp\u003eSupporting current ratings from \u003cstrong\u003e100A up to 1600A\u003c\/strong\u003e, with maximum ratings available up to \u003cstrong\u003e3150A\u003c\/strong\u003e, this switch is suitable for small industrial systems through heavy-duty power distribution installations.\u003c\/p\u003e\n\u003cp\u003eIts robust construction and \u003cstrong\u003eAC-22A utilization category\u003c\/strong\u003e capability make it ideal for switching mixed resistive and inductive loads while ensuring operational safety and equipment protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e✔ Heavy-duty industrial load break switch\u003cbr\u003e✔ Safe electrical isolation and load disconnection\u003cbr\u003e✔ 3 Pole switching configuration\u003cbr\u003e✔ Current ratings from \u003cstrong\u003e100A to 1600A\u003c\/strong\u003e\u003cbr\u003e✔ Maximum ratings available up to \u003cstrong\u003e3150A\u003c\/strong\u003e\u003cbr\u003e✔ Rated operational voltage up to \u003cstrong\u003e690VAC\u003c\/strong\u003e\u003cbr\u003e✔ Suitable for industrial power distribution systems\u003cbr\u003e✔ AC-22A utilization category\u003cbr\u003e✔ IEC 60947-2 compliant design\u003cbr\u003e✔ High reliability switching mechanism\u003cbr\u003e✔ Durable industrial-grade construction\u003cbr\u003e✔ External operating handle available upon request\u003cbr\u003e✔ Suitable for low-voltage electrical systems\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eHGL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLoad Break Switch (LBS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole Configuration\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Voltage\u003c\/td\u003e\n\u003ctd\u003e690VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUtilization Category\u003c\/td\u003e\n\u003ctd\u003eAC-22A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e100A – 1600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Available Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 3150A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eAvailable Models\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePole\u003c\/th\u003e\n\u003cth\u003eCurrent Rating\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-100\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e100A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-160\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e160A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-200\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e200A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-315\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e315A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-400\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e400A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-630\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e630A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-800\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e800A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-1250\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e1250A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHGL-1600\/3\u003c\/td\u003e\n\u003ctd\u003e3 Pole\u003c\/td\u003e\n\u003ctd\u003e1600A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial power distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommercial buildings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGenerator isolation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSolar power installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial automation infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSwitchgear panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical safety isolation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eDelixi HGL Load Break Switch Series\u003c\/strong\u003e provides secure circuit isolation, dependable switching performance, and reliable industrial power management for demanding electrical environments.\u003c\/p\u003e","brand":"delixi","offers":[{"title":"100A","offer_id":52573135700149,"sku":null,"price":12000.0,"currency_code":"PKR","in_stock":true},{"title":"160A","offer_id":52573135732917,"sku":null,"price":25000.0,"currency_code":"PKR","in_stock":true},{"title":"200A","offer_id":52573135765685,"sku":null,"price":38000.0,"currency_code":"PKR","in_stock":true},{"title":"315A","offer_id":52573135798453,"sku":null,"price":47000.0,"currency_code":"PKR","in_stock":true},{"title":"400A","offer_id":52573135831221,"sku":null,"price":49000.0,"currency_code":"PKR","in_stock":true},{"title":"630A","offer_id":52573135863989,"sku":null,"price":68000.0,"currency_code":"PKR","in_stock":true},{"title":"800A","offer_id":52573135896757,"sku":null,"price":130000.0,"currency_code":"PKR","in_stock":true},{"title":"1250A","offer_id":52573135929525,"sku":null,"price":0.0,"currency_code":"PKR","in_stock":true},{"title":"1600A","offer_id":52573135962293,"sku":null,"price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1015\/2021\/2149\/files\/32.png?v=1779879474","url":"https:\/\/www.zamteqelectric.com\/products\/hgl-3-pole-load-break-switch-100a-to-1600a-industrial-isolation-power-switching-solution","provider":"Zamteq Electric","version":"1.0","type":"link"}